gvtcx

PURCON848 Microscopes and Accessories

University of East Anglia Published 22 May 2019 Contracts Finder

key details

Statusactive
Category (CPV) 38510000 +2 more
RegionEast of England
Deadline20 Jun 2019
Contract start15 Jul 2019
Contract end22 May 2022
Procedureopen
SME suitableNo
OCIDocds-b5fd17-3cd39cbc-e7c9-43fc-98bf-bd26a32c315b

description

Confocal Microscope / Widefield, Fluorescence microscope / Field Emission Scanning Electron Microscope / 4. EM specimen preparation equipment

  1. A confocal microscope based on a fully-motorised, inverted stand with high NA objectives: 5x, 10x and 20x air, 40x and 60x water- or silicone-immersion, and 40x and 60x oil-immersion lenses. Fast focus control (e.g., piezo-controlled) for rapid Z-stack acquisition, precise stage control for image tiling, and a means of autofocus control in timelapse experiments that doesn't require sample illumination. Halogen and LED light-sources, filter sets for blue, green and orange/red fluorophores, and optics for brightfield, phase-contrast and DIC to aid sample localization. Six laser-lines for blue, cyan, green, yellow, red and far-red fluorophore excitation and the appropriate filters/diffraction gratings for the most sensitive detection. At least two detectors/cameras for simultaneous two-channel acquisition. For point-scanners at least two detectors should be GaAsP, or similar. For spinning-disc systems, the cameras should be sCMOS or EM-CCD. Facility to capture transmitted-light images (brightfield, phase-contrast and DIC) in combination with confocal images. The system should have the facility to collect images with a resolution of 120 x 120 x 350 nm. The system should be optimized to use the lowest achievable laser powers to avoid sample photodamage and fluorophore photobleaching. The microscope should also be able to collect a 512 x 512 pixel, confocal image in less than 25 msec, and a super-resolution image in less than 250 msec (for point-scanning systems this must be achieved without the use of a resonant scanner). Workstation with software for multi-channel, multi-position, timelapse, Z-stack acquisition, spectral scanning, and adequate RAM and disc-space to allow the fastest acquisition. Vibration-isolation table. Additional licence for a full version of the software. Three to five day on-site, after-sales training. Four-year, fully-comprehensive service contract.
  1. A widefield, fluorescence microscope based on a fully-motorized inverted stand with low-magnification objectives of long-working distance, and high magnification objectives giving high resolution: 2.5x (WD ~10 mm), 5x (WD ~10 mm), 10x (WD ~5 mm) and 20x (WD ~3 mm) air, 40x/1.1NA (WD ~600 ?m) water-immersion, 40x/1.4NA, 60x/1.4NA and 100x/1.4NA oil-immersion lenses. Fast focus control (e.g., piezo-controlled) for rapid Z-stack acquisition, precise stage control for image tiling, and a means of autofocus control in timelapse experiments that doesn't require sample illumination. Halogen/LED light source for transmitted light imaging (brightfield, phase-contrast and DIC). An LED light-source with multiple, individual LEDs for different fluorophores and matched filter sets for blue, green, red, far-red acquisition, and a dual-band filter set for eGFP/mCherry two-channel acquisition. Camera must be a front-illuminated, sCMOS ...

Additional information: Tender documents available from InTend, if interested please log on via the link below https://in-tendhost.co.uk/universityofeastanglia/aspx/Home

Is a Recurrent Procurement Type? : No

documents

Documents are linked, not mirrored. They are served by the publishing authority and may require registration.

notice history

1 notice published against this procurement.

PublishedTypeRegimeNotice
22 May 2019 Tender amendment (tenderAmendment) · 7b8604d7-4a6d-42c3-929e-0da137bb7e1d-290980

more from University of East Anglia

all contracts from this buyer →

similar contracts awarded

Other awarded contracts in the same category. Useful for seeing who normally wins this kind of work, and at what value.

source

Published on Contracts Finder. Contact details for named individuals are not reproduced on this site.