Ultrasonic Doppler Velocimetry (UDV) system
key details
| Value | £64,000 |
|---|---|
| Status | complete |
| Category (CPV) | 33112200 |
| Deadline | 19 Dec 2023 |
| Contract start | 1 Jan 2024 |
| Contract end | 31 Dec 2028 |
| Procedure | direct |
| SME suitable | No |
| OCID | ocds-b5fd17-c811f858-5cce-4516-83a3-1399b7e44524 |
Award
| Supplier | Value | Date | Status |
|---|---|---|---|
| Signal Processing SA | £64,000 | 19 Dec 2023 | active |
description
Voluntary Ex-Ante Transparency Notice
Awarded Supplier:
Signal Processing S.A.
Value of contract:
64,000.00 EUR
Justification for award:
UDV measurement systems operate by propagating ultrasonic waves through the liquid metal, allowing for measurements of the flow velocity without disturbing the flow. In the SmallLab set-up, sensors will be mounted on or within a test channel. The data gathered from the velocity measurements will be used to record the complex temporally and spatially variant flow structures that form within the volume of the liquid metal.
To provide valuable data for validation and benchmarking of computational fluid dynamics codes, high spatial and temporal resolution data is required. Increasing the number of sensors and implementing non-intrusive measurement techniques at multiple streamwise and spanwise locations of the flow domain is the key approach to providing the spatial resolution. To provide accurate temporal resolution, in conjunction with the spatial variability, the multiple sensors at each location must operate simultaneously to capture instantaneous data concurrently. This is especially important given the high temporal variability of flow structures. On the test facility, we must measure the velocities at at least 4 streamwise locations at instantaneously concurrent time points. Only by utilising this simultaneous data from multiple sensors can we build a virtual picture of the flow structures within the full liquid metal volume and accurately track their evolution in time. These fundamental requirements are reflected in the UDV specification, TD-0018378.
The technical lead on the project conducted extensive market research to identify potential suppliers for a UDV system that meets the defined specification. Consequently, only three possible suppliers were found.
After analysis of three UDV system providers identified and their technical offerings, only one supplier was determined to offer the specification required.
notice history
1 notice published against this procurement.
| Published | Type | Regime | Notice |
|---|---|---|---|
| 19 Dec 2023 | Award (award) | · | 01518c50-4e0b-4ce6-9c1f-4ad9b2f47b86-708641 |
more from United Kingdom Atomic Energy Authority
- Removal of Controlled Waste · £400,000 · 28 Oct 2025
- Fixed Crane Maintenance Service · £240,000 · 1 Aug 2025
- Pressure Assembly Fabricated from Stainless Steel Tubing for a Cryogenic Application in Vacuum for MAST-U · £1,000,000 · 2 Jul 2025
- Isolation Transformers · £35,000 · 14 Mar 2025
- Employee Assistance Programme · 11 Mar 2025
- IT Storage · £204,000 · 5 Mar 2025
- Cloud and Mobile, Environmental, Health and Safety Platform · £108,000 · 5 Mar 2025
- Procurement of OVX Systems · £4,800,000 · 4 Mar 2025
all contracts from this buyer →
similar contracts awarded
Other awarded contracts in the same category. Useful for seeing who normally wins this kind of work, and at what value.
- High-intensity focused ultrasound · Northampton General Hospital NHS Trust
- Supply of a Dynamic High Pressure Test Rig · Robert Gordon University · £250,000
- Provision of High intensity focused ultrasound (HIFU) · Royal United Hospitals Bath NHS Foundation Trust
- 5 yr maintenance service for 1x GE VIVID IQ ultrasound · King's College Trust · £16,920
- Ethicon Endo J&J ultrasonic generator x10 · King's College Trust · £18,000
- Bronze Service Plan · UK SHARED BUSINESS SERVICES LIMITED · £21,060
- Sonopet IQ · Leeds Teaching Hospitals NHS Trust · £63,018
- FM22145 - Ultraprobe System · UK SHARED BUSINESS SERVICES LIMITED · £14,105
source