gvtcx

HARBOUR AND EMERGENCY GENSET

ASTILLEROS GONDAN SA Published 2 Jun 2023 Contracts Finder

key details

Value£110,000
Statusactive
Category (CPV) 71000000
Deadline16 Jun 2023
Contract start1 Jun 2024
Contract end2 Jul 2025
Procedurelimited
SME suitableYes
OCIDocds-b5fd17-883f82a9-3577-4da4-b1f4-c0e6045e535f

description

Harbour and Emergency Diesel Generator Set

One (1) pc combined generator shall be provided, running on MGO only.

The Engine shall meet IMO TIER III requirements for emissions.

The generator shall supply the entire Vessel with power in emergency operation.

The generator shall be designed for standard requirements for an emergency generator.

The generator shall be designed for powering the vessel and/or the hybrid power bank batteries in Harbour Alternator mode.

When in Harbour Alternator Mode, the engine shall have additional engine shut down in way of High Jacket water temperature.

There shall be clear indication in the emergency generator room and on the ICAM on which mode is selected.

The diesel engine shall be 4-stroke, turbocharged and inter-cooled with direct injection of liquid fuel and electronic regulator. The rating shall be for continuous operation, fulfilling the e-load calculation. The diesel engine shall be fitted with electrical/water standstill heating.

The diesel engine shall be with 24 VDC electric starter and a hydraulic starter for emergency start.

The generator shall be for marine use, brushless type generators with interference VDE 0875, class N, or equivalent standards and the following particulars:

Voltage 3 Phase, 415 V, 50 Hz

Power factor Minimum 0.8

Speed TBC

Enclosure IP44, air cooled

Engine cooling Fresh water (Radiator with fan ventilation)

Alternator cooling Air cooled for marine operations Insulation Class H (NEMA classification) or equivalent Temperature rise Class F (NEMA classification) or equivalent Thermal sensor One in each stator winding plus spare in each winding Standstill heating Electrical/Water

The generator shall be equipped with:

Automatic Voltage Regulator, fuel oil tank with alarm, anti-condensation heater, and sensors for vibration analysis monitoring that shall be integrated into the vessel's Condition Monitoring system.

Local sensors: Lube oil pressure and temperature, fuel oil pressure, cooling water pressure and temperature, battery status, and header tank level.

documents

Documents are linked, not mirrored. They are served by the publishing authority and may require registration.

notice history

1 notice published against this procurement.

PublishedTypeRegimeNotice
2 Jun 2023 Tender (tender) · 5ceb3793-940f-4818-8e5d-201afb605352-650121

more from ASTILLEROS GONDAN SA

all contracts from this buyer →

similar contracts awarded

Other awarded contracts in the same category. Useful for seeing who normally wins this kind of work, and at what value.

source

Published on Contracts Finder. Contact details for named individuals are not reproduced on this site.